Lee et al., 2017 - Google Patents

Estimation of Compton imager using single 3D position-sensitive LYSO scintillator: Monte Carlo simulation

Lee et al., 2017

Document ID
12166334611495911363
Author
Lee T
Lee H
Kim Y
Lee W
Publication year
Publication venue
Journal of the Korean Physical Society

External Links

Snippet

The performance of a Compton imager using a single three-dimensional position-sensitive LYSO scintillator detector was estimated using a Monte Carlo simulation. The Compton imager consisted of a single LYSO scintillator with a pixelized structure. The size of the …
Continue reading at link.springer.com (other versions)

Classifications

    • GPHYSICS
    • G01MEASURING; TESTING
    • G01TMEASUREMENT OF NUCLEAR OR X-RADIATION
    • G01T1/00Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
    • G01T1/16Measuring radiation intensity
    • G01T1/161Application in the field of nuclear medicine, e.g. in vivo counting
    • G01T1/164Scintigraphy
    • G01T1/1641Static instruments for imaging the distribution of radioactivity in one or two dimensions using one or several scintillating elements; Radio-isotope cameras
    • G01T1/1648Ancillary equipment for scintillation cameras, e.g. reference markers, devices for removing motion artifacts, calibration devices
    • GPHYSICS
    • G01MEASURING; TESTING
    • G01TMEASUREMENT OF NUCLEAR OR X-RADIATION
    • G01T1/00Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
    • G01T1/29Measurement performed on radiation beams, e.g. position or section of the beam; Measurement of spatial distribution of radiation
    • G01T1/2914Measurement of spatial distribution of radiation
    • G01T1/2921Static instruments for imaging the distribution of radioactivity in one or two dimensions; Radio-isotope cameras
    • GPHYSICS
    • G01MEASURING; TESTING
    • G01TMEASUREMENT OF NUCLEAR OR X-RADIATION
    • G01T1/00Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
    • G01T1/29Measurement performed on radiation beams, e.g. position or section of the beam; Measurement of spatial distribution of radiation
    • G01T1/2914Measurement of spatial distribution of radiation
    • G01T1/2985In depth localisation, e.g. using positron emitters; Tomographic imaging (longitudinal and transverse section imaging; apparatus for radiation diagnosis sequentially in different planes, steroscopic radiation diagnosis)
    • GPHYSICS
    • G01MEASURING; TESTING
    • G01TMEASUREMENT OF NUCLEAR OR X-RADIATION
    • G01T1/00Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
    • G01T1/16Measuring radiation intensity
    • G01T1/20Measuring radiation intensity with scintillation detectors
    • G01T1/2018Scintillation-photodiode combination
    • GPHYSICS
    • G01MEASURING; TESTING
    • G01TMEASUREMENT OF NUCLEAR OR X-RADIATION
    • G01T1/00Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
    • G01T1/16Measuring radiation intensity
    • G01T1/24Measuring radiation intensity with semiconductor detectors
    • GPHYSICS
    • G01MEASURING; TESTING
    • G01TMEASUREMENT OF NUCLEAR OR X-RADIATION
    • G01T1/00Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
    • G01T1/16Measuring radiation intensity
    • G01T1/17Circuit arrangements not adapted to a particular type of detector
    • GPHYSICS
    • G01MEASURING; TESTING
    • G01TMEASUREMENT OF NUCLEAR OR X-RADIATION
    • G01T1/00Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
    • G01T1/02Dosimeters
    • GPHYSICS
    • G06COMPUTING; CALCULATING; COUNTING
    • G06TIMAGE DATA PROCESSING OR GENERATION, IN GENERAL
    • G06T2211/00Image generation
    • G06T2211/40Computed tomography
    • G06T2211/424Iterative
    • GPHYSICS
    • G01MEASURING; TESTING
    • G01NINVESTIGATING OR ANALYSING MATERIALS BY DETERMINING THEIR CHEMICAL OR PHYSICAL PROPERTIES
    • G01N23/00Investigating or analysing materials by the use of wave or particle radiation not covered by G01N21/00 or G01N22/00, e.g. X-rays or neutrons
    • G01N23/02Investigating or analysing materials by the use of wave or particle radiation not covered by G01N21/00 or G01N22/00, e.g. X-rays or neutrons by transmitting the radiation through the material
    • G01N23/04Investigating or analysing materials by the use of wave or particle radiation not covered by G01N21/00 or G01N22/00, e.g. X-rays or neutrons by transmitting the radiation through the material and forming a picture
    • GPHYSICS
    • G06COMPUTING; CALCULATING; COUNTING
    • G06TIMAGE DATA PROCESSING OR GENERATION, IN GENERAL
    • G06T11/002D [Two Dimensional] image generation
    • G06T11/003Reconstruction from projections, e.g. tomography
    • G06T11/006Inverse problem, transformation from projection-space into object-space, e.g. transform methods, back-projection, algebraic methods
    • GPHYSICS
    • G01MEASURING; TESTING
    • G01TMEASUREMENT OF NUCLEAR OR X-RADIATION
    • G01T7/00Details of radiation-measuring instruments

Similar Documents

Publication Publication Date Title
Xu et al. 4-pi Compton imaging with single 3D position-sensitive CdZnTe detector
US7888651B2 (en) Method and system for using tissue-scattered coincidence photons for imaging
US8274054B2 (en) Method and apparatus for imaging using robust bayesian sequence reconstruction
Kishimoto et al. Demonstration of three-dimensional imaging based on handheld Compton camera
Yabu et al. Tomographic Imaging by a Si/CdTe Compton Camera for ¹¹¹In and ¹³¹I Radionuclides
Shy et al. Gamma-ray tracking for high energy gamma-ray imaging in pixelated CdZnTe
Hecla et al. Polaris-lamp: Multi-modal 3-d image reconstruction with a commercial gamma-ray imager
Xu Gamma-ray imaging and polarization measurement using 3-D position-sensitive CdZnTe detectors
Karpetas et al. Detective quantum efficiency (DQE) in PET scanners: A simulation study
Beekman et al. Improvement of image resolution and quantitative accuracy in clinical single photon emission computed tomography
Lee et al. Estimation of Compton imager using single 3D position-sensitive LYSO scintillator: Monte Carlo simulation
Nuyts Nuclear medicine technology and techniques
Lee et al. Investigation of attenuation correction for small‐animal single photon emission computed tomography
Moslemi et al. Introducing a novel parallel hole collimator: the theoretical and Monte Carlo investigations
Hwang et al. Simulation of depth of interaction effects for pinhole SPECT
Zhang et al. Feasibility study of photon‐counting CT for material identification based on YSO/SiPM detector: A proof of concept
Lee et al. A Monte Carlo simulation study of the feasibility of a high resolution parallel-hole collimator with a CdTe pixelated semiconductor SPECT system
Hua Compton imaging system development and performance assessment
Lee et al. Adaptation of filtered back-projection to compton imaging with non-uniform azimuthal geometry
Lee et al. High-performance Compton SPECT using both photoelectric and Compton scattering events
Feng Modeling and regularization in tomographic reconstruction for Compton camera imaging
Lee et al. Development of an Independent and Interactive Compton Camera System Using Dual Arrays of Single Scintillator-based Camera Modules
Choi et al. Detection efficiency and imaging performance of a 25.4× 25.4× 24 mm3 compton camera based on a single voxelized scintillator
Durko Anamorphic preclinical SPECT imaging with high-resolution silicon double-sided strip detectors
Peterson SPECT Imaging using Pinhole Collimation: System Design and Simulation Studies for Pre-Clinical and Clinical Imaging