Estimation of Compton imager using single 3D position-sensitive LYSO scintillator: Monte Carlo simulationLee et al., 2017
- Document ID
- 12166334611495911363
- Author
- Lee T
- Lee H
- Kim Y
- Lee W
- Publication year
- Publication venue
- Journal of the Korean Physical Society
External Links
Snippet
The performance of a Compton imager using a single three-dimensional position-sensitive LYSO scintillator detector was estimated using a Monte Carlo simulation. The Compton imager consisted of a single LYSO scintillator with a pixelized structure. The size of the …
- 238000000342 Monte Carlo simulation 0 title abstract description 5
Classifications
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01T—MEASUREMENT OF NUCLEAR OR X-RADIATION
- G01T1/00—Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
- G01T1/16—Measuring radiation intensity
- G01T1/161—Application in the field of nuclear medicine, e.g. in vivo counting
- G01T1/164—Scintigraphy
- G01T1/1641—Static instruments for imaging the distribution of radioactivity in one or two dimensions using one or several scintillating elements; Radio-isotope cameras
- G01T1/1648—Ancillary equipment for scintillation cameras, e.g. reference markers, devices for removing motion artifacts, calibration devices
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01T—MEASUREMENT OF NUCLEAR OR X-RADIATION
- G01T1/00—Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
- G01T1/29—Measurement performed on radiation beams, e.g. position or section of the beam; Measurement of spatial distribution of radiation
- G01T1/2914—Measurement of spatial distribution of radiation
- G01T1/2921—Static instruments for imaging the distribution of radioactivity in one or two dimensions; Radio-isotope cameras
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01T—MEASUREMENT OF NUCLEAR OR X-RADIATION
- G01T1/00—Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
- G01T1/29—Measurement performed on radiation beams, e.g. position or section of the beam; Measurement of spatial distribution of radiation
- G01T1/2914—Measurement of spatial distribution of radiation
- G01T1/2985—In depth localisation, e.g. using positron emitters; Tomographic imaging (longitudinal and transverse section imaging; apparatus for radiation diagnosis sequentially in different planes, steroscopic radiation diagnosis)
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01T—MEASUREMENT OF NUCLEAR OR X-RADIATION
- G01T1/00—Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
- G01T1/16—Measuring radiation intensity
- G01T1/20—Measuring radiation intensity with scintillation detectors
- G01T1/2018—Scintillation-photodiode combination
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01T—MEASUREMENT OF NUCLEAR OR X-RADIATION
- G01T1/00—Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
- G01T1/16—Measuring radiation intensity
- G01T1/24—Measuring radiation intensity with semiconductor detectors
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01T—MEASUREMENT OF NUCLEAR OR X-RADIATION
- G01T1/00—Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
- G01T1/16—Measuring radiation intensity
- G01T1/17—Circuit arrangements not adapted to a particular type of detector
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01T—MEASUREMENT OF NUCLEAR OR X-RADIATION
- G01T1/00—Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
- G01T1/02—Dosimeters
-
- G—PHYSICS
- G06—COMPUTING; CALCULATING; COUNTING
- G06T—IMAGE DATA PROCESSING OR GENERATION, IN GENERAL
- G06T2211/00—Image generation
- G06T2211/40—Computed tomography
- G06T2211/424—Iterative
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01N—INVESTIGATING OR ANALYSING MATERIALS BY DETERMINING THEIR CHEMICAL OR PHYSICAL PROPERTIES
- G01N23/00—Investigating or analysing materials by the use of wave or particle radiation not covered by G01N21/00 or G01N22/00, e.g. X-rays or neutrons
- G01N23/02—Investigating or analysing materials by the use of wave or particle radiation not covered by G01N21/00 or G01N22/00, e.g. X-rays or neutrons by transmitting the radiation through the material
- G01N23/04—Investigating or analysing materials by the use of wave or particle radiation not covered by G01N21/00 or G01N22/00, e.g. X-rays or neutrons by transmitting the radiation through the material and forming a picture
-
- G—PHYSICS
- G06—COMPUTING; CALCULATING; COUNTING
- G06T—IMAGE DATA PROCESSING OR GENERATION, IN GENERAL
- G06T11/00—2D [Two Dimensional] image generation
- G06T11/003—Reconstruction from projections, e.g. tomography
- G06T11/006—Inverse problem, transformation from projection-space into object-space, e.g. transform methods, back-projection, algebraic methods
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01T—MEASUREMENT OF NUCLEAR OR X-RADIATION
- G01T7/00—Details of radiation-measuring instruments
Similar Documents
| Publication | Publication Date | Title |
|---|---|---|
| Xu et al. | 4-pi Compton imaging with single 3D position-sensitive CdZnTe detector | |
| US7888651B2 (en) | Method and system for using tissue-scattered coincidence photons for imaging | |
| US8274054B2 (en) | Method and apparatus for imaging using robust bayesian sequence reconstruction | |
| Kishimoto et al. | Demonstration of three-dimensional imaging based on handheld Compton camera | |
| Yabu et al. | Tomographic Imaging by a Si/CdTe Compton Camera for ¹¹¹In and ¹³¹I Radionuclides | |
| Shy et al. | Gamma-ray tracking for high energy gamma-ray imaging in pixelated CdZnTe | |
| Hecla et al. | Polaris-lamp: Multi-modal 3-d image reconstruction with a commercial gamma-ray imager | |
| Xu | Gamma-ray imaging and polarization measurement using 3-D position-sensitive CdZnTe detectors | |
| Karpetas et al. | Detective quantum efficiency (DQE) in PET scanners: A simulation study | |
| Beekman et al. | Improvement of image resolution and quantitative accuracy in clinical single photon emission computed tomography | |
| Lee et al. | Estimation of Compton imager using single 3D position-sensitive LYSO scintillator: Monte Carlo simulation | |
| Nuyts | Nuclear medicine technology and techniques | |
| Lee et al. | Investigation of attenuation correction for small‐animal single photon emission computed tomography | |
| Moslemi et al. | Introducing a novel parallel hole collimator: the theoretical and Monte Carlo investigations | |
| Hwang et al. | Simulation of depth of interaction effects for pinhole SPECT | |
| Zhang et al. | Feasibility study of photon‐counting CT for material identification based on YSO/SiPM detector: A proof of concept | |
| Lee et al. | A Monte Carlo simulation study of the feasibility of a high resolution parallel-hole collimator with a CdTe pixelated semiconductor SPECT system | |
| Hua | Compton imaging system development and performance assessment | |
| Lee et al. | Adaptation of filtered back-projection to compton imaging with non-uniform azimuthal geometry | |
| Lee et al. | High-performance Compton SPECT using both photoelectric and Compton scattering events | |
| Feng | Modeling and regularization in tomographic reconstruction for Compton camera imaging | |
| Lee et al. | Development of an Independent and Interactive Compton Camera System Using Dual Arrays of Single Scintillator-based Camera Modules | |
| Choi et al. | Detection efficiency and imaging performance of a 25.4× 25.4× 24 mm3 compton camera based on a single voxelized scintillator | |
| Durko | Anamorphic preclinical SPECT imaging with high-resolution silicon double-sided strip detectors | |
| Peterson | SPECT Imaging using Pinhole Collimation: System Design and Simulation Studies for Pre-Clinical and Clinical Imaging |