Compensation for spill-in and spill-out partial volume effects in cardiac PET imagingDu et al., 2013
View PDF- Document ID
- 8905660908879100873
- Author
- Du Y
- Madar I
- Stumpf M
- Rong X
- Fung G
- Frey E
- Publication year
- Publication venue
- Journal of Nuclear Cardiology
External Links
Snippet
Abstract Background Partial volume effects (PVEs) in PET imaging result in incorrect regional activity estimates due to both spill-out and spill-in from activity in neighboring regions. It is important to compensate for both effects to achieve accurate quantification. In …
- 230000000694 effects 0 title abstract description 148
Classifications
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B6/00—Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
- A61B6/50—Clinical applications
- A61B6/507—Clinical applications involving determination of haemodynamic parameters, e.g. perfusion CT
-
- G—PHYSICS
- G06—COMPUTING; CALCULATING; COUNTING
- G06T—IMAGE DATA PROCESSING OR GENERATION, IN GENERAL
- G06T2207/00—Indexing scheme for image analysis or image enhancement
- G06T2207/10—Image acquisition modality
- G06T2207/10072—Tomographic images
- G06T2207/10104—Positron emission tomography [PET]
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B6/00—Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
- A61B6/02—Devices for diagnosis sequentially in different planes; Stereoscopic radiation diagnosis
- A61B6/03—Computerised tomographs
- A61B6/032—Transmission computed tomography [CT]
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B6/00—Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
- A61B6/48—Diagnostic techniques
- A61B6/481—Diagnostic techniques involving the use of contrast agents
-
- G—PHYSICS
- G06—COMPUTING; CALCULATING; COUNTING
- G06T—IMAGE DATA PROCESSING OR GENERATION, IN GENERAL
- G06T2207/00—Indexing scheme for image analysis or image enhancement
- G06T2207/30—Subject of image; Context of image processing
- G06T2207/30004—Biomedical image processing
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B6/00—Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
- A61B6/02—Devices for diagnosis sequentially in different planes; Stereoscopic radiation diagnosis
- A61B6/03—Computerised tomographs
- A61B6/037—Emission tomography
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B6/00—Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
- A61B6/50—Clinical applications
- A61B6/504—Clinical applications involving diagnosis of blood vessels, e.g. by angiography
-
- G—PHYSICS
- G06—COMPUTING; CALCULATING; COUNTING
- G06T—IMAGE DATA PROCESSING OR GENERATION, IN GENERAL
- G06T2207/00—Indexing scheme for image analysis or image enhancement
- G06T2207/10—Image acquisition modality
- G06T2207/10072—Tomographic images
- G06T2207/10084—Hybrid tomography; Concurrent acquisition with multiple different tomographic modalities
-
- G—PHYSICS
- G06—COMPUTING; CALCULATING; COUNTING
- G06T—IMAGE DATA PROCESSING OR GENERATION, IN GENERAL
- G06T7/00—Image analysis
- G06T7/0002—Inspection of images, e.g. flaw detection
- G06T7/0012—Biomedical image inspection
- G06T7/0014—Biomedical image inspection using an image reference approach
-
- G—PHYSICS
- G06—COMPUTING; CALCULATING; COUNTING
- G06T—IMAGE DATA PROCESSING OR GENERATION, IN GENERAL
- G06T2207/00—Indexing scheme for image analysis or image enhancement
- G06T2207/10—Image acquisition modality
- G06T2207/10116—X-ray image
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B6/00—Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
- A61B6/58—Testing, adjusting or calibrating devices for radiation diagnosis
- A61B6/582—Calibration
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B6/00—Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
- A61B6/52—Devices using data or image processing specially adapted for radiation diagnosis
-
- G—PHYSICS
- G06—COMPUTING; CALCULATING; COUNTING
- G06T—IMAGE DATA PROCESSING OR GENERATION, IN GENERAL
- G06T11/00—2D [Two Dimensional] image generation
- G06T11/003—Reconstruction from projections, e.g. tomography
- G06T11/005—Specific pre-processing for tomographic reconstruction, e.g. calibration, source positioning, rebinning, scatter correction, retrospective gating
-
- G—PHYSICS
- G06—COMPUTING; CALCULATING; COUNTING
- G06T—IMAGE DATA PROCESSING OR GENERATION, IN GENERAL
- G06T2207/00—Indexing scheme for image analysis or image enhancement
- G06T2207/20—Special algorithmic details
- G06T2207/20212—Image combination
- G06T2207/20224—Image subtraction
-
- G—PHYSICS
- G06—COMPUTING; CALCULATING; COUNTING
- G06T—IMAGE DATA PROCESSING OR GENERATION, IN GENERAL
- G06T2211/00—Image generation
- G06T2211/40—Computed tomography
Similar Documents
| Publication | Publication Date | Title |
|---|---|---|
| Segars et al. | Application of the 4-D XCAT phantoms in biomedical imaging and beyond | |
| Erlandsson et al. | A review of partial volume correction techniques for emission tomography and their applications in neurology, cardiology and oncology | |
| McCollough et al. | Milestones in CT: past, present, and future | |
| EP2399238B1 (en) | Functional imaging | |
| Tsoumpas et al. | Fast generation of 4D PET-MR data from real dynamic MR acquisitions | |
| Dawood et al. | Respiratory motion correction in 3-D PET data with advanced optical flow algorithms | |
| Nestle et al. | Practical integration of [18F]-FDG-PET and PET-CT in the planning of radiotherapy for non-small cell lung cancer (NSCLC): the technical basis, ICRU-target volumes, problems, perspectives | |
| Si-Mohamed et al. | Head-to-head comparison of lung perfusion with dual-energy CT and SPECT-CT | |
| Du et al. | Compensation for spill-in and spill-out partial volume effects in cardiac PET imaging | |
| Bai et al. | Motion correction and attenuation correction for respiratory gated PET images | |
| Presotto et al. | Simultaneous reconstruction of attenuation and activity in cardiac PET can remove CT misalignment artifacts | |
| Sun et al. | An iterative image-based inter-frame motion compensation method for dynamic brain PET imaging | |
| Könik et al. | Comparison of methods of acquiring attenuation maps for cardiac SPECT in the presence of respiratory motion | |
| Chan et al. | Noise suppressed partial volume correction for cardiac SPECT/CT | |
| Li et al. | Radiation dose reduction in CT myocardial perfusion imaging using SMART-RECON | |
| JP4879472B2 (en) | Cerebral blood flow quantitative analysis program, recording medium, and cerebral blood flow image data processing method | |
| Coolens et al. | Quantification accuracy for dynamic contrast enhanced (DCE) CT imaging: phantom and quality assurance framework | |
| Chan et al. | Simultaneous partial volume correction and noise regularization for cardiac SPECT/CT | |
| Kalantari et al. | Attenuation correction in 4D‐PET using a single‐phase attenuation map and rigidity‐adaptive deformable registration | |
| Erlandsson | Partial volume correction in PET imaging | |
| Nye et al. | Current state of hybrid imaging: attenuation correction and fusion | |
| Da Silva et al. | Absolute in vivo quantitation of myocardial activity | |
| Huh et al. | Monte carlo simulation and reconstruction: assessment of myocardial perfusion imaging of tracer dynamics with cardiac motion due to deformation and respiration using gamma camera with continuous acquisition | |
| Lauzier et al. | Non-uniform noise spatial distribution in CT myocardial perfusion and a potential solution: statistical image reconstruction | |
| JP7487406B2 (en) | Sharpness-preserving breathing motion compensation |