Patterson et al., 2013 - Google Patents
A field investigation into the limits of high-density air-coolingPatterson et al., 2013
- Document ID
- 6646723880410442769
- Author
- Patterson M
- Martin R
- Von Oehsen J
- Pepin J
- Joshi Y
- Arghode V
- Steinbrecher R
- King J
- Publication year
- Publication venue
- International Electronic Packaging Technical Conference and Exhibition
External Links
Snippet
In this paper we report on a field investigation into airflow management challenges in high density data centers. This field investigation has also served to validate laboratory investigations into high density air cooling issues. In data centers with significant power …
- 238000001816 cooling 0 title abstract description 15
Classifications
-
- G—PHYSICS
- G06—COMPUTING; CALCULATING; COUNTING
- G06F—ELECTRICAL DIGITAL DATA PROCESSING
- G06F1/00—Details of data-processing equipment not covered by groups G06F3/00 - G06F13/00, e.g. cooling, packaging or power supply specially adapted for computer application
- G06F1/16—Constructional details or arrangements
- G06F1/20—Cooling means
-
- H—ELECTRICITY
- H05—ELECTRIC TECHNIQUES NOT OTHERWISE PROVIDED FOR
- H05K—PRINTED CIRCUITS; CASINGS OR CONSTRUCTIONAL DETAILS OF ELECTRIC APPARATUS; MANUFACTURE OF ASSEMBLAGES OF ELECTRICAL COMPONENTS
- H05K7/00—Constructional details common to different types of electric apparatus
- H05K7/20—Modifications to facilitate cooling, ventilating, or heating
- H05K7/20709—Modifications to facilitate cooling, ventilating, or heating for server racks or cabinets; for data centers, e.g. 19-inch computer racks
- H05K7/20718—Forced ventilation of a gaseous coolant
- H05K7/20745—Forced ventilation of a gaseous coolant within rooms for removing heat from cabinets, e.g. by air conditioning device
-
- G—PHYSICS
- G06—COMPUTING; CALCULATING; COUNTING
- G06F—ELECTRICAL DIGITAL DATA PROCESSING
- G06F1/00—Details of data-processing equipment not covered by groups G06F3/00 - G06F13/00, e.g. cooling, packaging or power supply specially adapted for computer application
- G06F1/16—Constructional details or arrangements
- G06F1/18—Packaging or power distribution
- G06F1/183—Internal mounting support structures, e.g. for printed circuit boards, internal connecting means
- G06F1/187—Mounting of fixed and removable disk drives
-
- H—ELECTRICITY
- H05—ELECTRIC TECHNIQUES NOT OTHERWISE PROVIDED FOR
- H05K—PRINTED CIRCUITS; CASINGS OR CONSTRUCTIONAL DETAILS OF ELECTRIC APPARATUS; MANUFACTURE OF ASSEMBLAGES OF ELECTRICAL COMPONENTS
- H05K7/00—Constructional details common to different types of electric apparatus
- H05K7/20—Modifications to facilitate cooling, ventilating, or heating
- H05K7/20009—Modifications to facilitate cooling, ventilating, or heating using a gaseous coolant in electronic enclosures
- H05K7/20136—Forced ventilation, e.g. by fans
- H05K7/20172—Fan mounting or fan specifications
-
- H—ELECTRICITY
- H05—ELECTRIC TECHNIQUES NOT OTHERWISE PROVIDED FOR
- H05K—PRINTED CIRCUITS; CASINGS OR CONSTRUCTIONAL DETAILS OF ELECTRIC APPARATUS; MANUFACTURE OF ASSEMBLAGES OF ELECTRICAL COMPONENTS
- H05K7/00—Constructional details common to different types of electric apparatus
- H05K7/20—Modifications to facilitate cooling, ventilating, or heating
- H05K7/20709—Modifications to facilitate cooling, ventilating, or heating for server racks or cabinets; for data centers, e.g. 19-inch computer racks
- H05K7/20763—Liquid cooling without phase change
-
- H—ELECTRICITY
- H05—ELECTRIC TECHNIQUES NOT OTHERWISE PROVIDED FOR
- H05K—PRINTED CIRCUITS; CASINGS OR CONSTRUCTIONAL DETAILS OF ELECTRIC APPARATUS; MANUFACTURE OF ASSEMBLAGES OF ELECTRICAL COMPONENTS
- H05K7/00—Constructional details common to different types of electric apparatus
- H05K7/20—Modifications to facilitate cooling, ventilating, or heating
- H05K7/20709—Modifications to facilitate cooling, ventilating, or heating for server racks or cabinets; for data centers, e.g. 19-inch computer racks
- H05K7/208—Liquid cooling with phase change
- H05K7/20809—Liquid cooling with phase change within server blades for removing heat from heat source
-
- H—ELECTRICITY
- H05—ELECTRIC TECHNIQUES NOT OTHERWISE PROVIDED FOR
- H05K—PRINTED CIRCUITS; CASINGS OR CONSTRUCTIONAL DETAILS OF ELECTRIC APPARATUS; MANUFACTURE OF ASSEMBLAGES OF ELECTRICAL COMPONENTS
- H05K7/00—Constructional details common to different types of electric apparatus
- H05K7/14—Mounting supporting structure in casing or on frame or rack
- H05K7/1485—Servers; Data center rooms, e.g. 19-inch computer racks
-
- G—PHYSICS
- G06—COMPUTING; CALCULATING; COUNTING
- G06F—ELECTRICAL DIGITAL DATA PROCESSING
- G06F2200/00—Indexing scheme relating to G06F1/04 - G06F1/32
- G06F2200/20—Indexing scheme relating to G06F1/20
Similar Documents
| Publication | Publication Date | Title |
|---|---|---|
| Joshi et al. | Energy efficient thermal management of data centers | |
| Patel et al. | Computational fluid dynamics modeling of high compute density data centers to assure system inlet air specifications | |
| US8764528B2 (en) | Systems and methods for closed loop heat containment with cold aisle isolation for data center cooling | |
| Arghode et al. | Thermal characteristics of open and contained data center cold aisle | |
| Patterson et al. | A field investigation into the limits of high-density air-cooling | |
| US20090122483A1 (en) | Water-assisted air cooling for a row of cabinets | |
| US20080300725A1 (en) | Identification and characterization of recirculation in electronic systems | |
| Karlsson et al. | Investigation of indoor climate and power usage in a data center | |
| CN102282428A (en) | Data centre and apparatus and method for data centre cooling | |
| Abdelmaksoud et al. | Improved CFD modeling of a small data center test cell | |
| Xiong et al. | A numerical investigation of fan wall cooling system for modular air-cooled data center | |
| Ghosh et al. | Effect of rack server population on temperatures in data centers | |
| Tradat et al. | Impact of elevated temperature on data center operation based on internal and external IT instrumentation | |
| Gao et al. | Comparative analysis of different in row cooler management configurations in a hybrid cooling data center | |
| US8672149B2 (en) | Thermochromic equipment rack | |
| Muralidharan et al. | Impact of cold aisle containment on thermal performance of data center | |
| US9372515B2 (en) | Heat and airflow management in a data storage device | |
| Gondipalli et al. | Effect of isolating cold aisles on rack inlet temperature | |
| Nemati et al. | Experimental characterization of a Rear Door Heat exchanger with localized containment | |
| Singh et al. | CFD-Based Operational Thermal Efficiency Improvement of a Production Data Center. | |
| Singh et al. | Innovative Retrofits for enhanced thermal performance in data centers using Independent Row-Based cooling systems | |
| Nemati et al. | Experimental failure analysis of a rear door heat exchanger with localized containment | |
| Lin et al. | The optimal thermal management study of a next-generation data center | |
| Kennedy | Ramification of server airflow leakage in data centers with aisle containment | |
| Venkatachalapathy et al. | Experimental and numerical investigation of mixed-convection heat transfer from protruding heat sources in an enclosure |