8000 GitHub - dekajoule/oos · GitHub
[go: up one dir, main page]

Skip to content
  • Pricing
  • Sign up
    dekajoulePublic

    About

    No description, website, or topics provided.

    Resources

    Code of conduct

    Contributing

    Security policy

    Stars

    197 stars

    Watchers

    1 watching

    Forks

    OOS: an open operating system for the Rigol DHO800/DHO900

    OOS replaces the software of a Rigol DHO800/DHO900 oscilloscope with a Linux 6.12 kernel and a new scope application written in Rust. It runs from the scope's own SD card, next to the stock system, and you can switch back at any time.

    Experimental software. Read the disclaimer before you install it. OOS has run on a DHO924S and, by user reports, on a DHO804 and a DHO802; several functions have never run on real hardware (status). Measurements made with OOS are not calibrated to any standard.

    Two channels: a 10:1 probe on the calibration signal and the built-in generator A square wave with its spectrum and peak list under it
    Eye diagram with TIE charts, bathtub and jitter breakdown Analog channel with three logic analyser lines

    All pictures are screenshots of a DHO924S running OOS. More in the gallery. How to install and use it is in the wiki: start here.

    Thanks

    OOS builds on the work of these projects. Thank you to everyone behind them:

    • NovaOS by Olympian LED, Inc., for publishing the GPL source of its Linux port to this hardware, which showed what a kernel needs here and where OOS started. The patches, device tree and configuration of the OOS kernel are written anew today. Its install notes also helped with the loader's image format.
    • Norbert Kiszka, for the findings about this hardware he shared in public.
    • Linux, the kernel underneath everything, and Rockchip for the board support it runs on here.
    • Xilinx XDMA driver, which connects the SoC to the FPGA over PCIe.
    • BusyBox, the userland of the image.
    • e2fsprogs by Theodore Ts'o, which checks the data partition at every start.
    • wpa_supplicant by Jouni Malinen and contributors, for WLAN.
    • linux-firmware and Realtek, for the firmware of the WLAN stick.
    • Rust and the libc crate, the only dependency of the OOS code on the scope.
    • Roboto, the typeface of the screen.

    Sources and licences of the kernel parts are listed in kernel/README.md.

    Contents

    Disclaimer

    Use OOS entirely at your own risk. OOS is provided "as is", without warranty of any kind, express or implied, including but not limited to merchantability, fitness for a particular purpose and non-infringement. To the maximum extent permitted by applicable law, the authors and contributors are not liable for any damage or loss arising from its use or from following these instructions. That includes damage to the instrument, to connected equipment or devices under test, loss of data or calibration, lost warranty, wrong measurements, injury and any consequential loss.

    Installing OOS means that you accept in particular the following risks:

    • Warranty. The boot card is inside the instrument. Installing OOS with a second card means opening the scope, and that voids the warranty. The USB install does not open it, but it changes the card, and nothing here promises that your warranty survives that. If it goes wrong, you may have to open the scope anyway.
    • Instrument damage. OOS drives the hardware directly: FPGA, ADC, front ends, sample clock, fan, relays and the generator output. A software fault can leave hardware in a state the stock firmware would never select. A failed fan control or a wrong setting can cause overheating or damage.
    • Data loss. A mistake while writing the card can make the scope unbootable or destroy the factory calibration stored on it. Without a good copy of your original card this data cannot be replaced.
    • Licences. Option licences of the stock system have been seen to stop working after running OOS, and had to be entered again. Keep your licence keys at hand.
    • Wrong measurements. OOS is not a calibrated or certified measuring instrument. Readings, trigger behaviour, decoders and analysis results can be wrong without any visible sign. Do not use OOS for safety-relevant, medical, legal, commercial or compliance measurements, and never rely on it to decide whether something is safe to touch.
    • Electrical safety. OOS changes nothing about the input ratings of the instrument. Observe the manufacturer's safety instructions and ratings. The open instrument contains a mains power supply with dangerous voltages. Disconnect the mains and all probes before you open it, and close it again before you connect mains. Only open it if you know how to do this safely.
    • Network security. Apart from SSH (password or key, docs/network.md 7), the only shell on the network, OOS has no authentication: SCPI, VXI-11, HiSLIP (on a computer), the web remote and MCP are open to everyone who can reach the scope. The community signing key is public, so anyone on the network can also install an update. This holds for WLAN as well. Connect the scope to a trusted bench network only, never directly to the internet.
    • Experimental settings. System > Overclock (with adc.overclock = on) and /oos/limits.conf can change the sample clock, limits.conf can also lift limits. Values outside the defaults are outside any rating and can make the scope unusable or damage it. Overclocked records lose samples at the full rate, so they are wrong: see docs/models.md.

    OOS is an independent project. It is not affiliated with, endorsed by or supported by RIGOL TECHNOLOGIES CO., LTD. Rigol and all other names are trademarks of their respective owners and are used here only to identify the hardware. Do not contact Rigol for support with OOS. The repository contains no Rigol code (how OOS is made). At run time OOS uses the FPGA image already in the scope's flash, the calibration files on its own card and the stock software on that card, which it needs to read the scope's identity. It only reads them.

    How OOS is made

    OOS is an independent reimplementation. The tree holds only descriptions of the scope's behaviour in our own words, and code written to them. The descriptions in docs/ are black-box: they say what goes in and what comes out at the scope's interfaces, that is the values its registers take and return, the words on the buses to the front ends, ADC, PLL and panel as they appear on a running unit, the signals at its inputs and outputs, the answers of the stock SCPI, and what Rigol publishes for users (the programming guide, the manuals) together with the data sheets of the parts. Each fact says how it is known (verified on the unit, assumed, or not yet verified on hardware). The tree holds no vendor code or data, and since ADR 0026 (2026-11-16) the same rule holds for every text around the code: commit messages, pull requests and issues.

    The decision records say this in detail: ADR 0030 (this rule), ADR 0013 (no vendor code or data), ADR 0015 (how a fact is known) and ADR 0026 (contributions).

    Supported models

    OOS reads the model from /rigol/data/vendor.bin at start and adapts channels, logic analyser, generator and EXT trigger to it. The stock software has to be on the card for that; without it, set model = ... in /oos/limits.conf. Details and limits: docs/models.md.

    Model Rated bandwidth Channels Logic analyser Generator EXT trigger Runs OOS
    DHO802 / DHO812 70 / 100 MHz 2 - - yes a DHO802 runs it (user report)
    DHO804 / DHO814 / DHO824 70 / 100 / 250 MHz 4 - - - a DHO804 runs it (user report)
    DHO914 / DHO924 125 / 250 MHz 4 yes - - not yet
    DHO914-EDU / DHO924-EDU 125 / 250 MHz 4 yes - - not yet
    DHO914S / DHO924S 125 / 250 MHz 4 yes yes - a DHO924S runs it (developer's unit)

    Each row is one hardware variant: its models differ only in the licensed bandwidth (docs/models.md 2.1), so a model whose row runs OOS counts as verified, and the USB install takes it without being told (docs/install-usb.md 4). The other models are prepared from the known model table and have never run OOS. The feature columns follow the model line-up; whether the EDU variants have the LA port is not confirmed. DHO1000, HDO1000/2000/4000 and MHO models are different boards and are not supported; docs/porting.md says what would carry over and how an owner can describe one.

    Limits on all models:

    1 channel 2 channels 3-4 channels
    Sample rate per channel 1.25 GSa/s 625 MSa/s 312.5 MSa/s
    Memory depth per channel 125 M 62.5 M 31.25 M
    Memory depth with the LA on 31.25 M 12.5 M 10 M

    For how the hardware works, see the hardware overview.

    What OOS does

    • Acquisition up to 1.25 GSa/s and 125 M points: normal, peak detect, average and high resolution, roll and scan mode, zoom, Auto with four views of the signal
    • Trigger: twelve hardware trigger types, protocol trigger on decoded bus events, zone trigger, noise reject
    • Display: waveform windows, up to four views to switch between, full screen, three text sizes, HDMI output, the picture drawn on the GPU
    • Measurement and maths: 35 automatic measurements with statistics, cursors, DVM, a frequency counter in the FPGA, a second pane (spectrum, results, events, trends), data logger, 8 math channels with free formulas, references, mask test
    • 29 protocol decoders, from UART, I2C and SPI to CAN-FD, MIL-STD-1553 and NMRA DCC
    • Analysers: spectrum, eye diagram and jitter, power, Bode with the built-in or an external generator, bandwidth test, Identify
    • Logic analyser with the PLA2216 probe, and the generator of S models
    • Remote control: web remote, SCPI, VXI-11, MCP for AI assistants, SSH, the scope by name over mDNS, and the desktop program oos-desktop for Windows, macOS and Linux
    • System: its own cold boot of all hardware, self-calibration into its own files, signed updates with trial start and automatic rollback

    Every feature in detail: Features.

    Gallery

    Results pane Trend pane
    Results pane: every measurement with statistics, peaks beside it Trend pane: two measurements over time
    Labels on the trace Spectrum
    Measurements labelled on the trace Spectrum view with its peak list
    Main screen System menu
    The main screen, 200 kHz from the built-in generator System menu
    Auto set-up views Full screen
    After Auto: a few periods, many periods, rising or falling edge Full screen, the same button goes back

    Status

    Area State
    Boot, cold boot, acquisition, trigger, roll and scan, touch, front panel, generator (sine, built-in Bode), self-calibration run on a DHO924S
    Signed updates from the web page and the shell, kexec trial start, trial and confirmation, install over ADB run on a DHO924S
    An update with another device tree, tried by kexec first (kexec-tools, from 0.1.7) run on a DHO924S: 0.1.6 to 0.1.7 to 0.1.8 through the web page, with cold starts
    System > Graphics = GPU, JPEG live picture from the video encoder run on a DHO924S, on the panel and with a 1920x1080 monitor in Mirror, Waveform and Layout
    Frequency counter in the FPGA, backlight, AC/DC by a long press run on a DHO924S (the counter with the built-in generator, 1.5 Hz to 9.9 MHz)
    Logic analyser with a PLA2216: lines, pulse widths, edge, pulse, pattern, duration and protocol trigger, UART, SPI and I2C on the lines, roll, scan, whole deep records, CSV run on a DHO924S, three lines (D0 to D2) driven; thresholds have no effect here, under stock neither
    Generator modulation (AM, FM, PM), deep memory, limits, web, MCP, VXI-11 run on a DHO924S
    HDMI output run on a DHO924S
    Automatic rollback of a bad update tests on the host only
    USB install without opening the scope run on a DHO924S with a modified stock system: dry run, first install, run again
    Generator noise, system info, bandwidth test tests on the host only
    Bode with a free-running sweep tests on the host only (synthetic sweeps); the scan path for sweeps above about 0.9 s is not yet tried on a unit
    Bode with a generator on USB (USBTMC), UNI-T UTG900 preset tests on the host only (a simulated USBTMC device); no generator on USB tried yet
    USB storage stick, 10:1 probe run on a DHO924S
    WLAN driver, firmware and scan run on a DHO924S with an RTL8188EU stick; joining a network tested on simulated radios only
    Overclocking (System > Overclock) run on a DHO924S: every step boots, but above 1.25 GHz records at the full rate lose samples; the default stays 1.25 GHz
    Spectrum, eye and jitter, results and trend panes, measurement labels, Auto run on a DHO924S with the generator and an RF source
    Protocol decoders tested with simulated signals; only some with real signals
    All models other than the DHO924S never run
    Hardware averaging, 800 ps/div not implemented

    The technical documents in docs/ say for each topic whether it is verified on the unit.

    Known limits:

    • Generator DC level: the output's middle jumps by about 85 mV where the generator switches its range at 2 Vpp. Whether the stock system shows the same is not known yet.
    • High resolution only gains where the record has more samples than the screen has points.
    • Logic analyser: D3 to D15 were not driven with a signal yet.
    • WLAN: joining a network has not been tried on the unit.

    Getting started

    The guides are in the wiki:

    Guide What it covers
    Installation from a USB stick without opening the scope, on a second card, or over ADB; the files of a release; how OOS starts
    First Steps the first start, the screen, Auto, windows and views, text size, saving, date and time, self-calibration
    Measurements and Analysers measurements, counter, panes, spectrum, eye, Bode, overclocking
    Generator, Logic Analyser the built-in generator of S models, the PLA2216 probe
    Remote Control, SCPI and VXI-11 web remote, network, WLAN, every remote interface and command
    Updates and Going Back new versions, rollback, returning to stock
    Troubleshooting what to do when something goes wrong
    Building building the image on macOS or Linux, trying OOS on a computer without a scope

    In one-shot mode, the default after an install, the next power-on starts the stock system again. OOS never writes the FPGA flash, /rigol/data, or the uboot, trust and parameter partitions.

    Repository layout

    The folders of the tree and what each holds: AGENTS.md, Layout of the tree. Besides them: keys/ (the public keys trusted for updates and the community signing key), CHANGELOG.md (what changed between releases), docs/README.md (the index of the technical documentation) and tools/README.md (the host tools, and which of them touch a scope).

    Development

    CONTRIBUTING.md says how to build, check and test a change, and how it gets into main. Coding agents, and people new to the tree, start with AGENTS.md; the hardware with the hardware overview and docs/architecture.md.

    Licences

    OOS is free software under the GNU General Public License, version 2 or (at your option) any later version. See LICENSE.

    Third-party parts keep their own licences. THIRD-PARTY-LICENSES.md lists every one of them with its version, its licence, where its licence text is and which source files go with a release: the Linux kernel and the XDMA driver, BusyBox, glibc and GCC's runtime, Mesa, libdrm and zlib (the GPU helper, gpu/README.md), e2fsck, kexec, wpa_supplicant with libnl, nftables with libmnl and libnftnl, Dropbear, OpenSSH's sftp-server, musl, the Rust standard library, the Roboto font, the wireless regulatory database and the RTL8188EU firmware. An image built from this tree carries the licence texts and that list under /etc/licenses.

    Every release carries the source archives of the binaries in its image next to the image. If you pass on an OOS image, the GPL requires you to provide the corresponding source as well: pass those archives and this tree at the release's tag on with it, or point to the release.

    About

    No description, website, or topics provided.

    Resources

    Code of conduct

    Contributing

    Security policy

    Stars

    197 stars

    Watchers

    1 watching

    Forks

    Releases

    Packages

    Contributors

    Languages

    0