| Applications of synthetic polymers in clinical medicine MF Maitz Biosurface and biotribology 1 (3), 161-176, 2015 | 951 | 2015 |
| Blood coagulation on biomaterials requires the combination of distinct activation processes C Sperling, M Fischer, MF Maitz, C Werner Biomaterials 30 (27), 4447-4456, 2009 | 340 | 2009 |
| Current strategies towards hemocompatible coatings C Werner, MF Maitz, C Sperling Journal of materials chemistry 17 (32), 3376-3384, 2007 | 303 | 2007 |
| The covalent immobilization of heparin to pulsed-plasma polymeric allylamine films on 316L stainless steel and the resulting effects on hemocompatibility Z Yang, J Wang, R Luo, MF Maitz, F Jing, H Sun, N Huang Biomaterials 31 (8), 2072-2083, 2010 | 266 | 2010 |
| Sperm micromotors for cargo delivery through flowing blood H Xu, M Medina-Sánchez, MF Maitz, C Werner, OG Schmidt ACS nano 14 (3), 2982-2993, 2020 | 262 | 2020 |
| The effect of coimmobilizing heparin and fibronectin on titanium on hemocompatibility and endothelialization G Li, P Yang, W Qin, MF Maitz, S Zhou, N Huang Biomaterials 32 (21), 4691-4703, 2011 | 246 | 2011 |
| A surface-eroding poly (1, 3-trimethylene carbonate) coating for fully biodegradable magnesium-based stent applications: toward better biofunction, biodegradation and … J Wang, Y He, MF Maitz, B Collins, K Xiong, L Guo, Y Yun, G Wan, ... Acta biomaterialia 9 (10), 8678-8689, 2013 | 199 | 2013 |
| In situ conformational analysis of fibrinogen adsorbed on Si surfaces S Tunc, MF Maitz, G Steiner, L Vázquez, MT Pham, R Salzer Colloids and Surfaces B: Biointerfaces 42 (3-4), 219-225, 2005 | 194 | 2005 |
| Bio-responsive polymer hydrogels homeostatically regulate blood coagulation MF Maitz, U Freudenberg, MV Tsurkan, M Fischer, T Beyrich, C Werner Nature Communications 4 (1), 2168, 2013 | 189 | 2013 |
| Assembly of metal–phenolic/catecholamine networks for synergistically anti-inflammatory, antimicrobial, and anticoagulant coatings X Li, P Gao, J Tan, K Xiong, MF Maitz, C Pan, H Wu, Y Chen, Z Yang, ... ACS applied materials & interfaces 10 (47), 40844-40853, 2018 | 176 | 2018 |
| Immobilization of heparin/poly-l-lysine nanoparticles on dopamine-coated surface to create a heparin density gradient for selective direction of platelet and vascular cells … T Liu, Y Liu, Y Chen, S Liu, MF Maitz, X Wang, K Zhang, J Wang, Y Wang, ... Acta Biomaterialia 10 (5), 1940-1954, 2014 | 168 | 2014 |
| Comparative corrosion behavior of Zn with Fe and Mg in the course of immersion degradation in phosphate buffered saline Y Chen, W Zhang, MF Maitz, M Chen, H Zhang, J Mao, Y Zhao, N Huang, ... Corrosion Science 111, 541-555, 2016 | 165 | 2016 |
| Biomimetic engineering endothelium-like coating on cardiovascular stent through heparin and nitric oxide-generating compound synergistic modification strategy H Qiu, P Qi, J Liu, Y Yang, X Tan, Y Xiao, MF Maitz, N Huang, Z Yang Biomaterials 207, 10-22, 2019 | 160 | 2019 |
| Mussel‐inspired coating of polydopamine directs endothelial and smooth muscle cell fate for re‐endothelialization of vascular devices Z Yang, Q Tu, Y Zhu, R Luo, X Li, Y Xie, MF Maitz, J Wang, N Huang Advanced healthcare materials 1 (5), 548-559, 2012 | 160 | 2012 |
| Endothelium-mimicking multifunctional coating modified cardiovascular stents via a stepwise metal-catechol-(amine) surface engineering strategy Y Yang, P Gao, J Wang, Q Tu, L Bai, K Xiong, H Qiu, X Zhao, MF Maitz, ... Research, 2020 | 155 | 2020 |
| Heparin desulfation modulates VEGF release and angiogenesis in diabetic wounds U Freudenberg, A Zieris, K Chwalek, MV Tsurkan, MF Maitz, P Atallah, ... Journal of Controlled Release 220, 79-88, 2015 | 153 | 2015 |
| A biocompatible and functional adhesive amine-rich coating based on dopamine polymerization Y Yang, P Qi, Y Ding, MF Maitz, Z Yang, Q Tu, K Xiong, Y Leng, N Huang Journal of Materials Chemistry B 3 (1), 72-81, 2015 | 153 | 2015 |
| Studies of surface modified NiTi alloy N Shevchenko, MT Pham, MF Maitz Applied surface science 235 (1-2), 126-131, 2004 | 152 | 2004 |
| Surface modification of cardiovascular materials and implants P Qi, MF Maitz, N Huang Surface and Coatings Technology 233, 80-90, 2013 | 151 | 2013 |
| The blood compatibility challenge. Part 4: Surface modification for hemocompatible materials: Passive and active approaches to guide blood-material interactions MF Maitz, MCL Martins, N Grabow, C Matschegewski, N Huang, ... Acta biomaterialia 94, 33-43, 2019 | 141 | 2019 |