[go: up one dir, main page]

Follow
Sonja Wegener
Sonja Wegener
Medical Physics Expert, University Hospital Würzburg
Verified email at ukw.de
Title
Cited by
Cited by
Year
Chiral particle separation by a nonchiral microlattice
L Bogunovic, M Fliedner, R Eichhorn, S Wegener, J Regtmeier, ...
Physical review letters 109 (10), 100603, 2012
382012
Prospective risk analysis of the online-adaptive artificial intelligence-driven workflow using the Ethos treatment system
S Wegener, F Exner, S Weick, S Stark, H Hutzel, P Lutyj, J Tamihardja, ...
Zeitschrift für Medizinische Physik 34 (3), 384-396, 2024
302024
Dielectrophoresis based continuous-flow nano sorter: fast quality control of gene vaccines
M Viefhues, S Wegener, A Rischmüller, M Schleef, D Anselmetti
Lab on a Chip 13 (15), 3111-3118, 2013
272013
Influence of the integral quality monitor transmission detector on high energy photon beams: a multi-centre study
B Casar, M Pasler, S Wegener, D Hoffman, C Talamonti, J Qian, I Mendez, ...
Zeitschrift Für Medizinische Physik 27 (3), 232-242, 2017
262017
Energy and field size dependence of a silicon diode designed for small‐field dosimetry
M Yarahmadi, S Wegener, OA Sauer
Medical Physics 44 (5), 1958-1964, 2017
212017
The effective point of measurement for depth‐dose measurements in small MV photon beams with different detectors
S Wegener, OA Sauer
Medical Physics 46 (11), 5209-5215, 2019
172019
Sensitivity of the IQM transmission detector to errors of VMAT plans
G Razinskas, S Wegener, J Greber, OA Sauer
Medical Physics 45 (12), 5622-5630, 2018
172018
Detector response in the buildup region of small MV fields
S Wegener, B Herzog, OA Sauer
Medical Physics 47 (3), 1327-1339, 2020
152020
The impact of isocentric shifts on delivery accuracy during the irradiation of small cerebral targets—Quantification and possible corrections
LJ Wack, F Exner, S Wegener, OA Sauer
Journal of Applied Clinical Medical Physics 21 (5), 56-64, 2020
142020
Influence of a transverse magnetic field on the response of different detectors in a high energy photon beam near the surface
S Wegener, S Weick, OA Sauer
Zeitschrift für Medizinische Physik 29 (1), 22-30, 2019
142019
Energy response corrections for profile measurements using a combination of different detector types
S Wegener, OA Sauer
Medical physics 45 (2), 898-907, 2018
142018
Separation of scatter from small MV beams and its effect on detector response
S Wegener, OA Sauer
Medical Physics 44 (3), 1139-1148, 2017
132017
Feasibility of Ethos adaptive treatments of lung tumors and associated quality assurance
S Wegener, S Weick, R Schindhelm, J Tamihardja, OA Sauer, ...
Journal of Applied Clinical Medical Physics 25 (7), e14311, 2024
112024
Dosimetric evaluation of commercially available flat vs. self-produced 3D-conformal silicone boluses for the head and neck region
S Pollmann, A Toussaint, M Flentje, S Wegener, V Lewitzki
Frontiers in Oncology 12, 881439, 2022
112022
Evaluation of the Ethos synthetic computed tomography for bolus-covered surfaces
S Wegener, R Schindhelm, J Tamihardja, OA Sauer, G Razinskas
Physica Medica 113, 102662, 2023
92023
Dose rate correction for a silicon diode detector array
A Jäger, S Wegener, OA Sauer
Journal of Applied Clinical Medical Physics 22 (10), 144-151, 2021
72021
Finer leaf resolution and steeper beam edges using a virtual isocentre in concurrence to PTV-shaped collimators in standard distance–a planning study
K Bratengeier, B Herzog, S Wegener, K Holubyev
Radiation Oncology 12 (1), 88, 2017
72017
Re-evaluation of the prospective risk analysis for artificial-intelligence driven cone beam computed tomography-based online adaptive radiotherapy after one year of clinical …
S Wegener, P Käthner, S Weick, R Schindhelm, K Breuer, S Stark, ...
Zeitschrift für Medizinische Physik 34 (3), 397-407, 2024
62024
On dosimetric characteristics of detectors for relative dosimetry in small fields: a multicenter experimental study
B Casar, I Mendez, E Gershkevitsh, S Wegener, D Jaffray, R Heaton, ...
Physics in Medicine & Biology 69 (3), 035009, 2024
62024
Sensitivity and specificity of Varian Halcyon's portal dosimetry for plan‐specific pre‐treatment QA
G Razinskas, R Schindhelm, OA Sauer, S Wegener
Journal of Applied Clinical Medical Physics 24 (8), e14001, 2023
62023
The system can't perform the operation now. Try again later.
Articles 1–20