False-negative driver cert when host reports driver version but no driver name #47
Running against a live ESXi 9.1 host, a RAID controller shows driver_certified: "N/A" even though its current_driver_version clearly matches an entry in supported_drivers (seen via -json):
The host's 90.4900.0.5000 matches the HCL base version 90.4900.0.5000 (from 90.4900.0.5000-3vmw.910), so this is a false-negative.
Root cause
For RAID/SAS/block HBAs on ESXi 9.1+, driver version + firmware are pulled via the raw SOAP call in parseHBAFirmwareFromSOAP (vsphere.go), which extracted firmwareVersion and driverVersion but not the <driver> (module name) element. So driver_name came back empty.
The matcher in hcl.go (evaluateVsanPCI) gated driver certification on the driver name — both the CertFalse baseline (DriverName != "" && DriverVer != "") and the version comparison (strings.Contains(res.DriverName, drvName)). With an empty name, the version comparison never ran, leaving the result at N/A.
Fix
Extract the <driver> module name in parseHBAFirmwareFromSOAP and carry it into the RAID/block HBA entries so driver_name is populated.
Add a version-only fallback in the matcher: when the host reports a driver version but no name, judge certification by matching the version against the device's already-PCI-matched supported drivers. Name matching stays enforced when a name is present (no blanket pass).