I have the same problem, however only when I upgrade the linux kernel. With kernel 3.19 it works for me, but once I upgrade to kernel 4.x.y I start getting that error.
If you try with mininet 2.2.1 it does work, but that mininet version is not supported by miniNExT (and I am not sure if it would be difficult to make it work). If you run mininet with "debug" option you can see what is going on, and maybe you are able to solve it. To do that edit the file start.py change setLogLevel('info') and put setLogLevel('debug').
If I find a way to fix that problem I will write it here. Tell us if you find a solution.
I was facing the same issue, and for me the problem behind was http://stackoverflow.com/questions/24932172/what-length-can-a-network-interface-name-have . The length of the network interface name cannot exceed 15/16 bytes, due to which the creation of interface was failing, and hence was unable to form a link ( This does not seem to be the case here, as the host names are pretty small ).
Yeah true, but my point is that it should not be failing silently. If the printError option is enabled, it would provide better visibility into what exactly the problem is.
@mjnovice To be clear, all of the code that controls setting up these network interfaces is in Mininet, not MiniNExT. I agree that it would be good to not 'hide' the errors in these cases, but that's not on MiniNExT's side.
I'm facing the same problem as you did with mininet 2.1.0p1 on Ubuntu 16.04, 4.4.0-31-generic
When I run the command
$ sudo mn --mac --switch=ovsk,protocols=OpenFlow13 --controller=remote,ip=127.0.0.1,port=6653 --topo=tree,3
I got :
*** Creating network
*** Adding controller
*** Adding hosts:
h1 h2 h3 h4 h5 h6 h7 h8
*** Adding switches:
s1 s2 s3 s4 s5 s6 s7
*** Adding links:
*** gave up after 3 retries
Have you solved the problem ? is there any proper solution there?
I stil experience this issue. The rm did not solve my problem. Could one of you clarify the issue?
I'll give it a shot. Here it goes.
The error is due to the network interface name exceeding 15/16 bytes. The workaround I did is to rename the switch to something shorter. Instead of 'fabric-sw1', I just used 'sw1'. You can validate this by setting the verbosity of the mininet script to "debug". Edit start.py and change the parameter of setLogLevel to 'debug' then launch the script. That should show which point in your code you're running into trouble.
My case its after a kernel upgrade from 3.x to 4.x. Right now I am trying to write my own miniNext so it works with my new kernel and mininet 2.2.1
@edgar-costa Did you manage to write your own version of miniNExT that works with kernel 4.x and supports some version of mininet different from 2.1.0? Can you please give me any feedback on what you have done (or tried) and was it successful?
Activity
edgar-costa commentedon Mar 12, 2016
I have the same problem, however only when I upgrade the linux kernel. With kernel 3.19 it works for me, but once I upgrade to kernel 4.x.y I start getting that error.
If you try with mininet 2.2.1 it does work, but that mininet version is not supported by miniNExT (and I am not sure if it would be difficult to make it work). If you run mininet with "debug" option you can see what is going on, and maybe you are able to solve it. To do that edit the file start.py change setLogLevel('info') and put setLogLevel('debug').
If I find a way to fix that problem I will write it here. Tell us if you find a solution.
Edgar
mjnovice commentedon Mar 14, 2016
I was facing the same issue, and for me the problem behind was http://stackoverflow.com/questions/24932172/what-length-can-a-network-interface-name-have . The length of the network interface name cannot exceed 15/16 bytes, due to which the creation of interface was failing, and hence was unable to form a link ( This does not seem to be the case here, as the host names are pretty small ).
This is silently failing because the mininet 2.1.0 (around which MiniNExT is built) https://github.com/mininet/mininet/blob/2.1.0/mininet/node.py ( line 355) is called without the printError option https://github.com/mininet/mininet/blob/2.1.0/mininet/util.py ( line 194). To prevent this from silently failing, either one could implement this function in the subclassed Host object adding the printError option in the call made at line 355.
mjnovice commentedon Mar 22, 2016
@sinhayash, @edgarcosta92 could you tell, if the above is the case ?
sinhayash commentedon Mar 22, 2016
Not sure, but I don't think I have used any interface 16 bytes long while running the above experiment, so it seems it is less likely to be the case
edgar-costa commentedon Mar 22, 2016
My case its after a kernel upgrade from 3.x to 4.x. Right now I am trying to write my own miniNext so it works with my new kernel and mininet 2.2.1
mjnovice commentedon Mar 23, 2016
Yeah true, but my point is that it should not be failing silently. If the printError option is enabled, it would provide better visibility into what exactly the problem is.
bschlinker commentedon Mar 23, 2016
@mjnovice To be clear, all of the code that controls setting up these network interfaces is in Mininet, not MiniNExT. I agree that it would be good to not 'hide' the errors in these cases, but that's not on MiniNExT's side.
LuizaNacshon commentedon Jul 27, 2016
Hey @sinhayash and all ,
I'm facing the same problem as you did with mininet 2.1.0p1 on Ubuntu 16.04, 4.4.0-31-generic
When I run the command
$ sudo mn --mac --switch=ovsk,protocols=OpenFlow13 --controller=remote,ip=127.0.0.1,port=6653 --topo=tree,3
I got :
*** Creating network
*** Adding controller
*** Adding hosts:
h1 h2 h3 h4 h5 h6 h7 h8
*** Adding switches:
s1 s2 s3 s4 s5 s6 s7
*** Adding links:
*** gave up after 3 retries
Have you solved the problem ? is there any proper solution there?
Thanks,
Luiza
chandanD4 commentedon Oct 31, 2016
Clear the older instance of mininet .. This issue could be due to mismatch .
execute following and give try . it should work
sudo rm -rf /usr/local/bin/mn /usr/local/bin/mnexec
/usr/local/lib/python_/_/mininet
/usr/local/bin/ovs-* /usr/local/sbin/ovs-*
demurgos commentedon Nov 10, 2017
I stil experience this issue. The
rmdid not solve my problem. Could one of you clarify the issue?jrtmendoza commentedon Apr 29, 2018
I'll give it a shot. Here it goes.
The error is due to the network interface name exceeding 15/16 bytes. The workaround I did is to rename the switch to something shorter. Instead of 'fabric-sw1', I just used 'sw1'. You can validate this by setting the verbosity of the mininet script to "debug". Edit start.py and change the parameter of setLogLevel to 'debug' then launch the script. That should show which point in your code you're running into trouble.
vladasov commentedon Jul 22, 2019
@edgar-costa Did you manage to write your own version of miniNExT that works with kernel 4.x and supports some version of mininet different from 2.1.0? Can you please give me any feedback on what you have done (or tried) and was it successful?
Thanks, Vladimir