8000 mininet/mininet/node.py at devel/cluster · scbzyhx/mininet · GitHub
[go: up one dir, main page]

Skip to content

Navigation Menu

Latest commit

 

History

History
1371 lines (1190 loc) · 51.4 KB

node.py

File metadata and controls

1371 lines (1190 loc) · 51.4 KB
# This may not be the right API,
# since it doesn't specify CPU bandwidth in "absolute"
# units the way link bandwidth is specified.
# We should use MIPS or SPECINT or something instead.
# Alternatively, we should change from system fraction
# to CPU seconds per second, essentially assuming that
# all CPUs are the same.
def setCPUFrac( self, f=-1, sched=None):
"""Set overall CPU fraction for this host
f: CPU bandwidth limit (fraction)
sched: 'rt' or 'cfs'
Note 'cfs' requires CONFIG_CFS_BANDWIDTH"""
if not f:
return
if not sched:
sched = self.sched
if sched == 'rt':
pstr, qstr, period, quota = self.rtInfo( f )
elif sched == 'cfs':
pstr, qstr, period, quota = self.cfsInfo( f )
else:
return
if quota < 0:
# Reset to unlimited
quota = -1
# Set cgroup's period and quota
self.cgroupSet( pstr, period )
self.cgroupSet( qstr, quota )
if sched == 'rt':
# Set RT priority if necessary
self.chrt()
info( '(%s %d/%dus) ' % ( sched, quota, period ) )
def setCPUs( self, cores, mems=0 ):
"Specify (real) cores that our cgroup can run on"
if type( cores ) is list:
cores = ','.join( [ str( c ) for c in cores ] )
self.cgroupSet( resource='cpuset', param='cpus',
value=cores )
# Memory placement is probably not relevant, but we
# must specify it anyway
self.cgroupSet( resource='cpuset', param='mems',
value=mems)
# We have to do this here after we've specified
# cpus and mems
errFail( 'cgclassify -g cpuset:/%s %s' % (
self.name, self.pid ) )
def config( self, cpu=None, cores=None, **params ):
"""cpu: desired overall system CPU fraction
cores: (real) core(s) this host can run on
params: parameters for Node.config()"""
r = Node.config( self, **params )
# Was considering cpu={'cpu': cpu , 'sched': sched}, but
# that seems redundant
self.setParam( r, 'setCPUFrac', cpu=cpu )
self.setParam( r, 'setCPUs', cores=cores )
return r
inited = False
@classmethod
def init( cls ):
"Initialization for CPULimitedHost class"
mountCgroups()
cls.inited = True
class HostWithPrivateDirs( Host ):
"Host with private directories"
def __init__( self, name, *args, **kwargs ):
"privateDirs: list of private directory strings or tuples"
self.name = name
self.privateDirs = kwargs.pop( 'privateDirs', [] )
Host.__init__( self, name, *args, **kwargs )
self.mountPrivateDirs()
def mountPrivateDirs( self ):
"mount private directories"
for directory in self.privateDirs:
if isinstance( directory, tuple ):
# mount given private directory
privateDir = directory[ 1 ] % self.__dict__
mountPoint = directory[ 0 ]
self.cmd( 'mkdir -p %s' % privateDir )
self.cmd( 'mkdir -p %s' % mountPoint )
self.cmd( 'mount --bind %s %s' %
( privateDir, mountPoint ) )
else:
# mount temporary filesystem on directory
self.cmd( 'mkdir -p %s' % directory )
self.cmd( 'mount -n -t tmpfs tmpfs %s' % directory )
# Some important things to note:
#
# The "IP" address which setIP() assigns to the switch is not
# an "IP address for the switch" in the sense of IP routing.
# Rather, it is the IP address for the control interface,
# on the control network, and it is only relevant to the
# controller. If you are running in the root namespace
# (which is the only way to run OVS at the moment), the
# control interface is the loopback interface, and you
# normally never want to change its IP address!
#
# In general, you NEVER want to attempt to use Linux's
# network stack (i.e. ifconfig) to "assign" an IP address or
# MAC address to a switch data port. Instead, you "assign"
# the IP and MAC addresses in the controller by specifying
# packets that you want to receive or send. The "MAC" address
# reported by ifconfig for a switch data port is essentially
# meaningless. It is important to understand this if you
# want to create a functional router using OpenFlow.
class Switch( Node ):
"""A Switch is a Node that is running (or has execed?)
an OpenFlow switch."""
portBase = 1 # Switches start with port 1 in OpenFlow
dpidLen = 16 # digits in dpid passed to switch
def __init__( self, name, dpid=None, opts='', listenPort=None, **params):
"""dpid: dpid hex string (or None to derive from name, e.g. s1 -> 1)
opts: additional switch options
listenPort: port to listen on for dpctl connections"""
Node.__init__( self, name, **params )
self.dpid = self.defaultDpid( dpid )
self.opts = opts
self.listenPort = listenPort
if not self.inNamespace:
self.controlIntf = Intf( 'lo', self, port=0 )
def defaultDpid( self, dpid=None ):
"Return correctly formatted dpid from dpid or switch name (s1 -> 1)"
if dpid:
# Remove any colons and make sure it's a good hex number
dpid = dpid.translate( None, ':' )
assert len( dpid ) <= self.dpidLen and int( dpid, 16 ) >= 0
else:
# Use hex of the first number in the switch name
nums = re.findall( r'\d+', self.name )
if nums:
dpid = hex( int( nums[ 0 ] ) )[ 2: ]
else:
raise Exception( 'Unable to derive default datapath ID - '
'please either specify a dpid or use a '
'canonical switch name such as s23.' )
return '0' * ( self.dpidLen - len( dpid ) ) + dpid
def defaultIntf( self ):
"Return control interface"
if self.controlIntf:
return self.controlIntf
else:
return Node.defaultIntf( self )
def sendCmd( self, *cmd, **kwargs ):
"""Send command to Node.
cmd: string"""
kwargs.setdefault( 'printPid', False )
if not self.execed:
return Node.sendCmd( self, *cmd, **kwargs )
else:
error( '*** Error: %s has execed and cannot accept commands' %
self.name )
def connected( self ):
"Is the switch connected to a controller? (override this method)"
return False and self # satisfy pylint
def __repr__( self ):
"More informative string representation"
intfs = ( ','.join( [ '%s:%s' % ( i.name, i.IP() )
for i in self.intfList() ] ) )
return '<%s %s: %s pid=%s> ' % (
self.__class__.__name__, self.name, intfs, self.pid )
class UserSwitch( Switch ):
"User-space switch."
dpidLen = 12
def __init__( self, name, dpopts='--no-slicing', **kwargs ):
"""Init.
name: name for the switch
dpopts: additional arguments to ofdatapath (--no-slicing)"""
Switch.__init__( self, name, **kwargs )
pathCheck( 'ofdatapath', 'ofprotocol',
moduleName='the OpenFlow reference user switch' +
'(openflow.org)' )
if self.listenPort:
self.opts += ' --listen=ptcp:%i ' % self.listenPort
else:
self.opts += ' --listen=punix:/tmp/%s.listen' % self.name
self.dpopts = dpopts
@classmethod
def setup( cls ):
"Ensure any dependencies are loaded; if not, try to load them."
if not os.path.exists( '/dev/net/tun' ):
moduleDeps( add=TUN )
def dpctl( self, *args ):
"Run dpctl command"
listenAddr = None
if not self.listenPort:
listenAddr = 'unix:/tmp/%s.listen' % self.name
else:
listenAddr = 'tcp:127.0.0.1:%i' % self.listenPort
return self.cmd( 'dpctl ' + ' '.join( args ) +
' ' + listenAddr )
def connected( self ):
"Is the switch connected to a controller?"
return 'remote.is-connected=true' in self.dpctl( 'status' )
@staticmethod
def TCReapply( intf ):
"""Unfortunately user switch and Mininet are fighting
over tc queuing disciplines. To resolve the conflict,
we re-create the user switch's configuration, but as a
leaf of the TCIntf-created configuration."""
if type( intf ) is TCIntf:
ifspeed = 10000000000 # 10 Gbps
minspeed = ifspeed * 0.001
res = intf.config( **intf.params )
if res is None: # link may not have TC parameters
return
# Re-add qdisc, root, and default classes user switch created, but
# with new parent, as setup by Mininet's TCIntf
parent = res['parent']
intf.tc( "%s qdisc add dev %s " + parent +
" handle 1: htb default 0xfffe" )
intf.tc( "%s class add dev %s classid 1:0xffff parent 1: htb rate "
+ str(ifspeed) )
intf.tc( "%s class add dev %s classid 1:0xfffe parent 1:0xffff " +
"htb rate " + str(minspeed) + " ceil " + str(ifspeed) )
def start( self, controllers ):
"""Start OpenFlow reference user datapath.
Log to /tmp/sN-{ofd,ofp}.log.
controllers: list of controller objects"""
# Add controllers
clist = ','.join( [ 'tcp:%s:%d' % ( c.IP(), c.port )
for c in controllers ] )
ofdlog = '/tmp/' + self.name + '-ofd.log'
ofplog = '/tmp/' + self.name + '-ofp.log'
self.cmd( 'ifconfig lo up' )
intfs = [ str( i ) for i in self.intfList() if not i.IP() ]
self.cmd( 'ofdatapath -i ' + ','.join( intfs ) +
' punix:/tmp/' + self.name + ' -d %s ' % self.dpid +
self.dpopts +
' 1> ' + ofdlog + ' 2> ' + ofdlog + ' &' )
self.cmd( 'ofprotocol unix:/tmp/' + self.name +
' ' + clist +
' --fail=closed ' + self.opts +
' 1> ' + ofplog + ' 2>' + ofplog + ' &' )
if "no-slicing" not in self.dpopts:
# Only TCReapply if slicing is enable
sleep(1) # Allow ofdatapath to start before re-arranging qdisc's
for intf in self.intfList():
if not intf.IP():
self.TCReapply( intf )
def stop( self ):
"Stop OpenFlow reference user datapath."
self.cmd( 'kill %ofdatapath' )
self.cmd( 'kill %ofprotocol' )
self.deleteIntfs()
class OVSLegacyKernelSwitch( Switch ):
"""Open VSwitch legacy kernel-space switch using ovs-openflowd.
Currently only works in the root namespace."""
def __init__( self, name, dp=None, **kwargs ):
"""Init.
name: name for switch
dp: netlink id (0, 1, 2, ...)
defaultMAC: default MAC as unsigned int; random value if None"""
Switch.__init__( self, name, **kwargs )
self.dp = dp if dp else self.name
self.intf = self.dp
if self.inNamespace:
error( "OVSKernelSwitch currently only works"
" in the root namespace.\n" )
exit( 1 )
@classmethod
def setup( cls ):
"Ensure any dependencies are loaded; if not, try to load them."
pathCheck( 'ovs-dpctl', 'ovs-openflowd',
moduleName='Open vSwitch (openvswitch.org)')
moduleDeps( subtract=OF_KMOD, add=OVS_KMOD )
def start( self, controllers ):
"Start up kernel datapath."
ofplog = '/tmp/' + self.name + '-ofp.log'
quietRun( 'ifconfig lo up' )
# Delete local datapath if it exists;
# then create a new one monitoring the given interfaces
self.cmd( 'ovs-dpctl del-dp ' + self.dp )
self.cmd( 'ovs-dpctl add-dp ' + self.dp )
intfs = [ str( i ) for i in self.intfList() if not i.IP() ]
self.cmd( 'ovs-dpctl', 'add-if', self.dp, ' '.join( intfs ) )
# Run protocol daemon
clist = ','.join( [ 'tcp:%s:%d' % ( c.IP(), c.port )
for c in controllers ] )
self.cmd( 'ovs-openflowd ' + self.dp +
' ' + clist +
' --fail=secure ' + self.opts +
' --datapath-id=' + self.dpid +
' 1>' + ofplog + ' 2>' + ofplog + '&' )
0